Climax climatic chambers keep together with fitting Agitators your thrombocytes in motion and at constant 22°C. Climax 150 and Climax 200 dispose of a maximum number of glass doors so that during door openings only a minimum temperature exchange with the outside environment takes place. The compressor of Climax series works extremly efficient to keep energy consumption at a very low level. Strong air recirculation and connected quick temperature adaption also account for the low energy consumption. The included temperature alarm system works idependently from the temperature controller (double temperature control).
Characteristics
Housing made of double-side epoxy laminated steel
Interior made of stainless steel (18/19 AISI 304), exterior laminated in white
Small rolls with fixing break
Produced of chrome-plated steel
Temperature control 22 °C +/- 1 °C.
Electronically controlled heating and cooling system
Air circulating fan for the fast assimilation of the target temperature
Isolation: the cavity between the two metal walls is packed 5 cm with the foam material polyurethane
Hung-in Glass Door: 3x isolation glass embedded in the aluminium frame
Framework: lined with refrigerator seal; external door handle
Stained steel plating: as footprint for Platelet agitator
Prepared inner wall: for placing of an external measurement probe
Integrated Temperature Recording: including separate temperature probe
New features for more reliable and safe storage of thrombocytes:
Door alarm included
Temperature alarm included
Faulty condenser alarm (too high condensing temperature)
Faulty evaporator alarm (too high evaporating temperature)
Faulty sensor alarm (Climax will work correctly in standard mode until technical interference)
RS 485 In/Out Interface as extension module
Complete temperature tracking with SD card incl. download interface software (memory of all temperature and operation data for a period of about 5 years)
Back up battery in case of power failure for the alarm system for up to 12 hours
2 Output relays (dry contact)
Memory of all temperature and operation data for a period of maximum 5 years
Saves working status, open door logs and any change in parameter settings
Digital printer for a weekly printout or other data
Printer
Display
The new Controller
The temperature controller at the highest stage
0,1°C accuracy
0,1°C measuring steps
Menu with 5 language options
Self-monitoring on the main settings allows to identify alarms and faulty conditions immediately
Password to control access (User, Service staff)
Stop-on-door, Second cooling und advanced defrosting allow an efficient managing of the defrost cycles, reducing thermal variations and consumption
Options
Web light server allows access to the device from a computer and multiconnection of refrigerators
Remote panel as option
PT 100 extension module in combination with PT 100 sensors enables calibration of the device
GSM Communication module (for sms communication)
CLIMAX 100
CLIMAX 150
CLIMAX 200
CLIMAX 120
Technical data
CLIMAX 100
CLIMAX 120
CLIMAX 150
CLIMAX 200
External dimensions (cm)
60,5x61x86,5
121x71x87,5
60,5x71x201,5
121x71x201.5
Internal dimensions (cm)
52,5x39,5x48
111x46,5x46
50,5x44,5x46 (x3 chambers in height)
111x44,5x46 (x3 chambers in height)
Capacity
1 x Agitator 24/48
2x Agitator 24/48 or 1x Agitator 96
3x Agitator 24 or 3x Agitator 48
6x Agitator 24/48 or 3x Agitator 96
Finished and packed unit
(cm)66x70x109 (kg) 75
(cm)127x80x107 (kg) 137
(cm)73x85x222 (kg) 205
(cm)135x85x222 (kg) 325
The measurements of the Climax without packing(cm)